2008 |
25 | EE | Yuji Ikedo,
Takako Morita,
Daisuke Fukuoka,
Takeshi Hara,
Hiroshi Fujita,
Etsuo Takada,
Tokiko Endo:
Computerized Classification of Mammary Gland Patterns in Whole Breast Ultrasound Images.
Digital Mammography / IWDM 2008: 188-195 |
24 | EE | Gobert N. Lee,
Daisuke Fukuoka,
Yuji Ikedo,
Takeshi Hara,
Hiroshi Fujita,
Etsuo Takada,
Tokiko Endo,
Takako Morita:
Classification of Benign and Malignant Masses in Ultrasound Breast Image Based on Geometric and Echo Features.
Digital Mammography / IWDM 2008: 433-439 |
23 | EE | Takeshi Hara,
Daisuke Fukuoka,
Yuji Ikedo,
Etsuo Takada,
Hiroshi Fujita,
Tokiko Endo,
Takako Morita:
Development of Whole Breast Ultrasound Viewer and Automated Mass Detection System.
Digital Mammography / IWDM 2008: 455-462 |
22 | EE | Hiroshi Fujita,
Yoshikazu Uchiyama,
Toshiaki Nakagawa,
Daisuke Fukuoka,
Yuji Hatanaka,
Takeshi Hara,
Gobert N. Lee,
Yoshinori Hayashi,
Yuji Ikedo,
Xin Gao,
Xiangrong Zhou:
Computer-aided diagnosis: The emerging of three CAD systems induced by Japanese health care needs.
Computer Methods and Programs in Biomedicine 92(3): 238-248 (2008) |
2007 |
21 | EE | Hiroshi Fujita,
Yoshikazu Uchiyama,
Toshiaki Nakagawa,
Daisuke Fukuoka,
Yuji Hatanaka,
Takeshi Hara,
Yoshinori Hayashi,
Yuji Ikedo,
Gobert N. Lee,
Xin Gao,
Xiangrong Zhou:
CAD on Brain, Fundus, and Breast Images.
MIMI 2007: 358-366 |
20 | EE | Xuejun Zhang,
Hiroshi Fujita,
Tuanfa Qin,
Jinchuang Zhao,
Masayuki Kanematsu,
Takeshi Hara,
Xiangrong Zhou,
Ryujiro Yokoyama,
Hiroshi Kondo,
Hiroaki Hoshi:
CAD on Liver Using CT and MRI.
MIMI 2007: 367-376 |
19 | EE | Ryujiro Yokoyama,
Xuejun Zhang,
Yoshikazu Uchiyama,
Hiroshi Fujita,
Takeshi Hara,
Xiangrong Zhou,
Masayuki Kanematsu,
Takahiko Asano,
Hiroshi Kondo,
Satoshi Goshima,
Hiroaki Hoshi,
Toru Iwama:
Development of an Automated Method for the Detection of Chronic Lacunar Infarct Regions in Brain MR Images.
IEICE Transactions 90-D(6): 943-954 (2007) |
2006 |
18 | EE | Gobert N. Lee,
Takeshi Hara,
Hiroshi Fujita:
Classifying Masses as Benign or Malignant Based on Co-occurrence Matrix Textures: A Comparison Study of Different Gray Level Quantizations.
Digital Mammography / IWDM 2006: 332-339 |
17 | EE | Takeshi Hara,
Takanari Makita,
Tomoko Matsubara,
Hiroshi Fujita,
Yoriko Inenaga,
Tokiko Endo,
Takuji Iwase:
Automated Detection Method for Architectural Distortion with Spiculation Based on Distribution Assessment of Mammary Gland on Mammogram.
Digital Mammography / IWDM 2006: 370-375 |
16 | EE | Daisuke Fukuoka,
Yuji Ikedo,
Takeshi Hara,
Hiroshi Fujita,
Etsuo Takada,
Tokiko Endo,
Takako Morita:
Development of Breast Ultrasound CAD System for Screening.
Digital Mammography / IWDM 2006: 392-398 |
15 | EE | Xiangrong Zhou,
Teruhiko Kitagawa,
Takeshi Hara,
Hiroshi Fujita,
Xuejun Zhang,
Ryujiro Yokoyama,
Hiroshi Kondo,
Masayuki Kanematsu,
Hiroaki Hoshi:
Constructing a Probabilistic Model for Automated Liver Region Segmentation Using Non-contrast X-Ray Torso CT images.
MICCAI (2) 2006: 856-863 |
2004 |
14 | | Shinji Kobayashi,
Xiangrong Zhou,
Takeshi Hara,
Hiroshi Fujita,
Ryujiro Yokoyama,
Takuji Kiryu,
Hiroaki Hoshi:
Automated identification of thoracic cage region from X-ray CT images.
CARS 2004: 1357 |
13 | | Yuji Hatanaka,
Yusuke Sakakibara,
Takeshi Hara,
Hiroshi Fujita,
Akira Aoyama,
Tetsuya Yamamoto:
Development of an automated method for detecting abnormal blood vessels on retinal images.
CARS 2004: 1363 |
12 | | Tomoko Matsubara,
Tetsuko Ichikawa,
Takeshi Hara,
Hiroshi Fujita,
Satoshi Kasai,
Tokiko Endo,
Takuji Iwase:
Novel method for detecting mammographic architectural distortion based on concentration of mammary gland.
CARS 2004: 867-871 |
11 | | Toshiaki Nakagawa,
Takeshi Hara,
Hiroshi Fujita,
Takuji Iwase,
Tokiko Endo,
Katsuhei Horita:
Automated contour extraction of mammographic mass shadow using an improved active contour model.
CARS 2004: 882-885 |
2003 |
10 | | Xiangrong Zhou,
Shigeaki Kobayashi,
Tatsuro Hayashi,
N. Murata,
Takeshi Hara,
Hiroshi Fujita,
Ryujiro Yokoyama,
Takuji Kiryu,
Hiroaki Hoshi,
Machiko Sato:
Lung structure recognition - a further study of thoracic organ recognitions based on CT Images.
CARS 2003: 1025-1030 |
9 | | Takeshi Hara,
Akira Yamamoto,
Xiangrong Zhou,
Shingo Iwano,
Shigeki Itou,
Hiroshi Fujita,
Takeo Ishigaki:
Automated volume measurements of pulmonary emphysema on 3D chest CT images.
CARS 2003: 1043-1048 |
8 | | Xuejun Zhang,
Masayuki Kanematsu,
Hiroshi Fujita,
Takeshi Hara,
Hiroshi Kondo,
Xiangrong Zhou,
Wenguang Li,
Hiroaki Hoshi:
Compute-aided differentiation of focal liver lisease in MR imaging.
CARS 2003: 1063-1069 |
7 | | Tomoko Matsubara,
Tetsuko Ichikawa,
Takeshi Hara,
Hiroshi Fujita,
Satoshi Kasai,
Tokiko Endo,
Takuji Iwase:
Automated detection methods for architectural distortions around skinline and within mammary gland on mammograms.
CARS 2003: 950-955 |
2001 |
6 | | Tomoko Matsubara,
D. Yamazaki,
M. Kato,
Takeshi Hara,
Hiroshi Fujita,
Takuji Iwase,
Tokiko Endo:
An automated classification scheme for mammograms based on amount and distribution of fibroglandular breast tissue density.
CARS 2001: 545-552 |
5 | | Yuji Hatanaka,
Takeshi Hara,
Hiroshi Fujita,
Satoshi Kasai,
Tokiko Endo,
Takuji Iwase:
An automated detection method of mammographic masses existing around thick-mammary-gland and near chest-wall regions.
CARS 2001: 560-566 |
4 | | Takeshi Hara,
Akitsugu Yamada,
Hiroshi Fujita,
Norimitsu Shinohara,
Katsuhei Horita,
Takuji Iwase,
Tokiko Endo:
Contrast correction method for detecting microcalcifications on mammograms by using step-wedge index.
CARS 2001: 567-572 |
3 | | Yuji Hatanaka,
Takeshi Hara,
Hiroshi Fujita,
Satoshi Kasai,
Tokiko Endo,
Takuji Iwase:
Development of an Automated Method for Detection Mammographic Masses with a Partial Loss of Region.
IEEE Trans. Med. Imaging 20(12): 1209-1214 (2001) |
2 | | Yongbum Lee,
Takeshi Hara,
Hiroshi Fujita:
Automated Detection of Pulmonary Nodules in Helical CT Images Based on an Improved Template-matching Technique.
IEEE Trans. Med. Imaging 20(7): 595-604 (2001) |
1999 |
1 | EE | Takeshi Hara,
Hiroshi Fujita,
Yongbum Lee,
Hitoshi Yoshimura,
Shoji Kido:
Automated Lesion Detection Methods for 2D and 3D Chest X-Ray Images.
ICIAP 1999: 768-773 |